Gas heats most homes here
Utility gas heats close to half the homes in Clark County, with electricity close behind. A mini split works alongside either, so an existing furnace or electric system doesn't need to go anywhere.
Takes about a minute. No obligation.
Utility gas heats close to half the homes in Clark County, with electricity close behind. A mini split works alongside either, so an existing furnace or electric system doesn't need to go anywhere.
Homes without a way to cool the house, or with one room a central system never quite reaches, are the usual case for this job. The mini split covers that room on its own, separate from however the rest of the house gets heated.

NOAA nClimDiv, 1991–2020 normals
Cooling starts in May here.
Get the mini split in during April and it's running before you need it.




A mini split sized for Clark County doesn't need any special math. Summer afternoons average 86°F here, which is normal cooling work, not extreme heat. Cooling runs May through September, about five months, and the unit sits idle the rest of the year. Zone 4A asks a system to handle both a real winter and a real summer, but that's what standard equipment is built for. There's no reason to size up or pay more for this climate than you would anywhere else rated the same way.
Clark County falls under zone 4A. Any mini split installed here has to meet the federal minimum for that class. That means 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. The standard treats a ductless system the same as any other split-system heat pump, with no separate rule for it. A federal tax credit is available for equipment that meets these minimums.
Find a contractorIf this is replacing a window unit or an old ductless system, someone has to deal with what comes out. A window unit just lifts out. A ductless system means a line set run through the wall, a disconnect, and the old indoor and outdoor units coming down. The refrigerant in the old system has to be recovered before anything gets disconnected, not vented. Whoever pulls the old unit should patch the wall penetration once the new line set goes in, or leave it ready for the new install to use the same path. None of this changes what size or tier the new unit needs. That part was already decided by the room and the climate zone, not by what it's replacing.
A single-zone system runs one indoor head off one outdoor unit. A multi-zone runs several heads, each with its own thermostat, off one outdoor unit. If you want more than one room covered, ask whether the quote is a multi-zone outdoor unit or separate single-zone systems. A multi-zone saves outdoor space, but if that outdoor unit fails, every room running off it loses heating and cooling at once.
Systems rated the same can call for very different installs. The distance from the outdoor unit to the indoor head matters, but so does how many bends the line set makes and how many walls or stories it crosses. Every bend is a joint, and every joint is a place a refrigerant leak can start down the road. A contractor who walks the actual route before quoting is telling you something a contractor who just asks for square footage is not.
Sizing a mini split starts with the room, not a chart. A contractor measures the space, checks what the walls and windows are doing, and counts anything else that adds heat, like a kitchen or a wall of glass. That gets weighed against what the room loses heat through in winter. Too big and the unit short cycles, cooling the room fast then shutting off before it pulls the moisture out of the air, so the room feels cold and damp instead of right. Too small and it runs flat out on the hottest and coldest days and still doesn't catch up. The goal is a unit that runs long, steady cycles most of the time, because that's when a mini split is doing its job well. None of this is guesswork a homeowner needs to do themselves, but it's worth knowing why the contractor is asking about window size and insulation before they ever talk about equipment.
Install day starts outside with the outdoor unit, mounted on a pad or brackets where it has clearance on all sides to pull in air. Inside, the indoor head gets mounted high on the wall, on a bracket set level so condensate drains the way it should. The crew drills one hole through the wall for the line set, the refrigerant lines, power wire, and the condensate drain all bundled together and run through it. Once the indoor and outdoor units are connected, the line set gets vacuumed down to pull out air and moisture before any refrigerant moves through it. Skip that step and moisture left in the lines turns to acid or ice down the road. After that the system gets charged, powered up, and run through both heating and cooling so you can feel it working before anyone packs up.
