An outdoor air conditioning condenser unit mounted on a concrete pad next to a blue-sided residential house at sunset.

AC Maintenance in Evansville, IN

Tell us about the job

Takes about a minute. No obligation.

Tune-up, service, or cleaningCentral ACVanderburgh County, IN
Step 1 of 2

What ZIP code is the job in?

Power here costs more to waste

Electricity in Vanderburgh County runs 19.78 cents per kilowatt-hour, higher than most of the country. An air conditioner that has to work harder than it should, because of a dirty coil or a low charge, burns through that expensive power every time it runs.

The air here makes it work harder

Summer dew points average 67°F here, which is heavy, sticky air that makes a system run longer just to pull moisture out of the house. A unit that isn't maintained loses efficiency right when it has the most work to do.

5 months
May through September, your air conditioner is on duty
87°F
the average summer afternoon it cools against
19 hail events
in ten years, and hail bends the fins on outdoor coils
103 wind events
in ten years, and wind drives debris into outdoor units
Isometric line illustration of a cutaway house showing interior rooms with furniture, ductwork leading to an indoor air handler, and an outdoor condenser unit connected by a line set.
Your air conditioner works hardest from June through August.

NOAA nClimDiv, 1991–2020 normals

A refrigerant charge reads low or high before the system ever trips a breaker or stops cooling.

That reading tells a technician the coil is starving for refrigerant or flooding with it, long before the compressor pays the price.

Half the homes here were built by 1970, and the AC inside them has had decades to fall behind

Half the homes here were built by 1970
Cooling runs May through September
Summer afternoons average 87°F
May starts the work. April is when to check it.Cooling runs May through September here. Have it looked at before the first month hits.

If your house is one of the half built by 1970, nobody can tell you from the paperwork what's been replaced and what hasn't. A yearly check is how you find that out. A technician can look at the coil, check the charge, and tell you whether the system is running the way it should or quietly losing ground. Catching a worn part during a tune-up means a repair. Catching it mid-summer, when the system is running flat out, means a breakdown instead. The older the system, the more that yearly look matters, because small problems have had more years to turn into bigger ones.

Fix it now, before it shows up on the bill

A system that has to work harder than it should burns through power that already costs more here than in most places. A tune-up finds the dirty coil or the low charge before it shows up on the bill.

Find a contractor
A man in a cap, worn gray shirt and brown work pants, seen from behind, carries a leather tool bag up steps toward an orange front door beside a potted shrub.
An outdoor residential air conditioning condenser unit mounted on a concrete pad, surrounded by gravel with a blue sky in the background.

What to check yourself, and what to leave alone

Between visits, the filter is the one thing worth checking yourself. A dirty filter chokes airflow across the coil, and a coil that can't get airflow struggles to pull heat out of the house no matter how well everything else is running. Look at it, and if light doesn't pass through it easily, swap it. Outside, keep the area around the condenser clear. Grass clippings, leaves, and anything piled against the cabinet block the airflow it needs to dump heat. A couple feet of open space on every side is enough. Keep the vents inside the house open and unblocked by furniture or rugs, since closing off rooms to save money actually forces the system to work harder against the pressure. Beyond that, leave it alone. The refrigerant charge, the electrical connections, the condensate drain, those aren't things to check without the right gauges and training, and opening up the cabinet yourself risks a shock or a bent fin that makes the system run worse, not better. If the system short cycles, blows warm air, or the outdoor unit makes a new noise, that's not a between-visits fix. That's a sign to get it looked at before the next scheduled visit rolls around.

The system tells you before it fails outright

Warm air from a vent that used to run cold, ice on the lines, a hissing or bubbling sound near the indoor coil. These show up while the system is still running, not after it quits. A unit low on refrigerant will keep trying to cool the house and keep falling short, and that gap between how long it runs and how cool the house gets is the clearest sign something underneath needs a look.

Short cycling wears out the parts that start it

An air conditioner that shuts off a few minutes after starting, then kicks back on, is short cycling. Every start draws a hard jolt of current through the compressor and the start components, and a system doing that all day is stacking up that wear fast. Left alone, short cycling is usually what takes out a compressor years before it should have quit.

An outdoor central air conditioning unit mounted on a concrete pad beside a blue-sided house at sunset.

Book your AC tune-up in April, before homes here start needing cooling in May.

  1. Jan
  2. Feb
  3. Mar
  4. Apr
  5. May
  6. Jun
  7. Jul
  8. Aug
  9. Sep
  10. Oct
  11. Nov
  12. Dec

A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.

A tune-up starts with the coils. The evaporator coil sits inside, where the air from the house passes over it, and the condenser coil sits outside, where the heat gets dumped. Dirt on either one acts like a blanket, so a technician cleans both rather than wiping down whichever one is easy to reach. From there it's the refrigerant charge, checked against the pressures the system is supposed to run at, not just topped off by guess. The condensate drain gets cleared, because a clogged one backs up and spills water where it shouldn't. Electrical connections get checked and tightened, since a loose one runs hot and can fail the part it feeds. The capacitor and contactor get tested under load, not just looked at, because a capacitor can read fine sitting still and still fail the moment the compressor asks it for a jolt. Fan motors get checked for play in the bearings and for amperage draw that's climbing past what it should. None of this fixes a problem that's already visible. It's meant to catch the one that isn't yet.