A row of dark-clad single-story houses with gabled roofs behind trimmed hedges, lawn and leafy trees under an overcast sky.

Heat Pump Repair in Crawfordsville, IN

Tell us about the job

Takes about a minute. No obligation.

RepairHeat PumpMontgomery County, IN
Step 1 of 2

What ZIP code is the job in?

Heating does most of the work here

Montgomery County sits in zone 5A, a cool, humid climate where heating carries the bigger load most of the year. Winter nights average 21°F. A heat pump here spends more time pulling heat in than pushing it out, which is steady work, not strain.

That makes repair the right call

A heat pump that isn't fighting extreme heat every summer tends to hold up well mechanically. When one here is acting up, age or a worn part is the more likely cause, not years of overwork. That usually means a repair is worth doing rather than a sign the unit is done.

8 months
October through May, your system heats
3 months
June through August, it cools
21°F
the average winter night it heats against
83°F
the average summer afternoon it cools against
Isometric cutaway illustration of a single-story house showing interior rooms with furniture, an attic duct network connected to a furnace or air handler, and an outdoor condenser unit linked by lines outside the wall.
Your system heats October through May and cools June through August.

NOAA nClimDiv, 1991–2020 normals

Heat here runs October through May, with September the month it switches on.

A weak part in a heat pump usually shows itself the first cold week it has to work.

A heat pump running weak here still runs up a bill at 14.77 cents a kWh

Power costs 14.77 cents a kWh statewide
20 hail events from 2015 to 2024
8 winter storms from 2015 to 2024

Half the homes in Montgomery County were built in 1967 or earlier. A heat pump doesn't last as long as the house around it, so if yours came with the place, it's probably not the original unit, and whatever is running now has its own age worth knowing. If nobody's told you how old it is, that's worth finding out before you put money into a repair. A failing compressor or reversing valve on an older unit is a different call than the same part failing on one installed a few years ago.

It's usually worth repairing

It has an easier job here than in most places, so your heat pump is often in decent shape. Repair is usually worth it.

Find a contractor
A man in a dark long-sleeve shirt and tan work pants walks up concrete steps toward an orange front door, carrying a waxed canvas tool bag in his right hand, with a potted shrub beside the gray-sided house.
A gray air-source heat pump mounted on a concrete pad next to a house with gray vinyl siding, surrounded by gravel and flanked by green shrubs and white hydrangea flowers.

Check the tag before you decide

Find the age tag on the unit before you agree to anything. It's on a sticker inside the cabinet, usually behind the lower access panel, with a manufacture date. If nobody can find it, the model and serial number on that same sticker will get you the date from the manufacturer. Know that before a tech quotes you a repair.

A refrigerant leak gets worse, not better

A heat pump low on refrigerant makes the compressor work harder to move heat from outside air into the house. Run it that way long enough and the compressor runs hotter than it should on every cycle. That shortens its life or kills it outright. A small leak found early is a repair. A compressor burned out from running low is a much bigger job.

A failing part strains the ones around it

A weak capacitor makes the compressor or fan motor draw hard every time it tries to start. A struggling defrost control leaves ice building on the outdoor coil instead of clearing it off. Either way, the parts nearby end up doing extra work on top of their own job, and that wears them down too. Shutting the system off when something seems off is simple. Running it means a tech may be replacing more than the one part that failed.

Before anyone comes out, there are a few things worth checking yourself. Look at the thermostat first. Make sure it's set to heat, not auto or cool, and that the set temperature is actually above room temperature. Go outside and look at the outdoor unit. If the coil is caked in ice or buried in leaves and debris, that airflow problem could be the whole issue. Check the indoor filter too. A filter clogged with dust chokes off airflow the same way a blocked outdoor coil does, and a heat pump starved of airflow on either side will struggle to keep up no matter what else is working right. If you've got a breaker panel you can get to safely, check that nothing's tripped. None of this fixes a bad compressor or a refrigerant leak, but it rules out the simple stuff before you pay someone to find it for you.

A diagnostic visit starts outside, at the unit itself. A tech checks the pressures in the line and the temperature of the air coming off the coil before a single panel comes off. Those readings point toward a refrigerant problem, an airflow problem, or an electrical one. From there it's gauges and a multimeter. The capacitor gets tested. The compressor's amp draw gets checked. The reversing valve gets watched to see how it responds when it's told to switch directions. A failing part usually tells on itself this way, a capacitor reading weak or a compressor pulling more current than it should. A unit blowing cold air or barely running can mean more than one thing, and the only way to tell them apart is to measure what's actually happening rather than guess from how it sounds or feels.