June is when it gets tested
Cooling in Putnam County runs June through August, about three months a year. May is worth a check before that first hot stretch, because whatever strain is coming hits in those first weeks of June.
Takes about a minute. No obligation.
Cooling in Putnam County runs June through August, about three months a year. May is worth a check before that first hot stretch, because whatever strain is coming hits in those first weeks of June.
An air conditioner that has sat unused for months doesn't show its problems until it has to run hard. If a capacitor or contactor was already marginal, the first real June heat is what finishes it off. Finding that part matters more than guessing at it.

NOAA nClimDiv, 1991–2020 normals
Three months of real heat is what this system has to handle here, June through August.
That's an ordinary summer's work, so a repeat breakdown points to a part that was never fixed right the first time.




If your house is one of the newer ones here, that's worth telling the contractor when they come out. A system in a newer home has usually had a straightforward install, standard ductwork, nothing retrofitted around old wiring or added on. That means when something breaks, it's almost always a single failed part doing it, not some underlying issue with the place. Worth asking what actually failed and why, instead of just having it swapped and sent on its way.
Problems tend to show up in the first weeks of the season, when the load hits a part that was already weak.
Find a contractor
Most air conditioner failures trace back to a handful of parts, and they tend to go the same way every time. The capacitor holds a charge that gives the compressor and fan motor their initial push. Over years of starting and stopping, it loses that capacity, and the motor it serves either struggles to start or does not start at all. The contactor is the switch that sends power to the outdoor unit. Its contacts pit and burn from repeated arcing until the connection gets unreliable. The run capacitor and the contactor fail more often than anything else in the system because they do the most cycling. Refrigerant leaks show up differently. The system does not use up refrigerant the way an engine uses oil, so a low charge almost always means a leak somewhere in the coil or the line set, and topping it off without finding the leak just delays the same call. A dirty condenser coil forces the compressor to work harder against heat it cannot shed, and that extra strain is what pushes a weak capacitor or a tired compressor past the point of no return. None of these are rare or unusual problems. They are the ordinary wear points in a machine that starts and stops thousands of times over its life, and finding which one actually failed is what separates a real repair from a part swapped on a guess.
Check the thermostat first. Make sure it's set to cool and set lower than the room temperature, and that the batteries aren't dead if it has them. Go to the breaker panel and look for a tripped breaker, both the one for the indoor air handler and the one for the outdoor unit. Check the filter. A filter clogged with dust blocks airflow across the indoor coil, and that alone can make the system blow warm or shut off on its own. Look at the outdoor unit and clear away any leaves, grass clippings or mulch piled against it. Some units have a float switch near the indoor coil that shuts the system off when a drain line backs up. If that switch has tripped, the system won't run until the drain is clear.
Don't take the outdoor unit's panel off or touch anything inside it. The capacitor in there holds a charge even after the power is cut, enough to hurt someone who doesn't know where it is or how to discharge it. Don't try to add refrigerant yourself. It's a sealed system under pressure, and handling it without the right equipment and license isn't something a homeowner can safely do. If the breaker trips again after you reset it, stop resetting it. A breaker that trips twice is telling you something downstream is drawing too much power, and running it again risks the compressor.
Estimates for a typical Putnam County home, compared with an older unit built to the previous federal minimum, from EIA household energy data, Indiana fuel prices and NOAA climate normals. Your home will differ.
Repair makes sense when a part like a capacitor or contactor has failed.
Replacement makes sense when the compressor has failed or the system uses R-22 refrigerant, which is no longer made.
A diagnostic visit starts with questions, not tools. What's the system doing, when did it start, does it run at all or just blow warm air. From there a tech checks the electrical side first, because a dead capacitor or a burnt contactor shows itself fast with a meter in hand. Refrigerant pressure gets checked too, both the suction and the liquid side, since those numbers point to whether the charge is low and where a leak might be hiding. The coils get a look, indoor and outdoor, because a coil caked in dust or grime changes how the whole system performs even when every part is technically working. A real diagnosis ends with a part named and a reason it failed, not a guess dressed up as a repair.