Two disconnects, two chances to find it off
The outdoor unit has its own pull-handle disconnect near the compressor, separate from the breaker panel. If someone pulled it for other work and forgot to reseat it, the unit stays dead.

A heat pump that won't turn on usually comes down to power not reaching it or the thermostat not calling for it. Check the breaker first, including the one at the outdoor unit, since a tripped breaker is the most common reason the system looks dead. If the breaker is fine, the thermostat batteries or settings can be the problem, or a safety switch has shut the system down because of a clogged filter or a frozen coil. Winters here get cold enough that ice on the outdoor unit is a real possibility, and a heat pump won't run while it's trying to defrost or while a frozen coil is tripping its safety switch. If power and thermostat both check out and the unit still won't start, the issue is likely inside the system itself, in the control board, the contactor, or the compressor, and that calls for someone who works on heat pumps to find out which one. Left alone, a heat pump that won't start means no heat until it's fixed.


A furnace just needs a call for heat and a flame. A heat pump has more steps, because it has to move heat instead of make it. The thermostat sends a low voltage signal to a control board, the board energizes a contactor, and the contactor is what actually pulls power into the compressor. Any break in that chain, a failed contactor, a bad board, a blown low voltage fuse, and the unit sits there looking dead even though power is reaching the house fine.
Outside, there's a separate disconnect box near the compressor, usually a pull handle, and it's wired apart from your breaker panel. It can be off, or stuck, while everything inside the house reads normal.
Cold weather adds another step. The unit periodically reverses itself to melt frost off the outdoor coil, controlled by a defrost board. If that board gets stuck mid-cycle, the system can sit there not responding, and it looks the same from the thermostat as a unit that's simply off.
Many systems store a lockout code for exactly this reason, on the thermostat display or on the outdoor board itself, pointing to which part of the circuit tripped first.
And if you've got auxiliary heat strips backing up the heat pump, they'll keep pushing warm air out of the vents even if the compressor outside has already quit, which is why the house can still feel heated while the heat pump itself is down.




The outdoor unit has its own pull-handle disconnect near the compressor, separate from the breaker panel. If someone pulled it for other work and forgot to reseat it, the unit stays dead.
The defrost control board manages both heating and the reversing valve. A furnace has neither part, so a heat pump that won't start can fail in ways a gas furnace never will.

It's past midnight in August and you're still awake, on top of the sheets instead of under them. The window shows a thin ring of fog at the edges where the humidity meets the cooler glass, except the room isn't cooler. You already checked the thermostat twice. You get up and go to the breaker panel in your socks, and then outside in the grass to the disconnect box by the compressor, flashlight in your teeth, and nothing's tripped that you can see. Tomorrow you're looking up contractors, calling the ones that answer, saying the same two sentences about the breaker and the humming to each one before you even get to someone who can come out.
Your request stays with one local pro.
Asking costs nothing, and the choice to hire stays yours.

The unit outside sits on its pad and the conduit runs clean up to the disconnect box on the wall. When a heat pump is calling and getting power, you'll hear the outdoor fan turn and feel warm or cool air moving at the vents inside within a few minutes.

Same setup, same wall, and the unit sits silent. No fan turning, no hum from the compressor. The conduit still runs down to the disconnect, which is the first thing worth checking, since a pulled or half-seated handle there will stop the whole system cold.
A hum with no start means the unit is getting power but the compressor or fan motor can't turn over. It's a different problem than a dead system, and it usually means a part has failed rather than a switch being off somewhere. You want to know what's actually making that sound before you decide whether this is something to call about.
The hum is the motor trying to start without enough of a push to get moving. A capacitor stores the charge that kicks the compressor or fan into motion, and when it weakens, the motor draws power and strains against it instead of turning. You'll sometimes hear the outdoor fan twitch or shudder instead of spinning freely. A seized compressor makes a similar sound, lower and steadier, and it won't clear on its own. Either way the unit keeps pulling power while it hums, which is hard on the parts around it the longer it's left running like that. This is a part needing replacement, not a reset or a breaker to flip.

Summers in Indiana run humid, with a dew point that averages 64°F across June, July and August, according to NOAA climate data. That kind of air is heavy, and a heat pump works through more of it just to pull the moisture out along with the heat. If yours won't start on one of those thick, still afternoons, the strain of a full summer like that is often what pushed a weak part past the point of still working. A compressor or capacitor that's been struggling against that load may finally quit right when you need the system most.
NASA POWER T2MDEW county cells weighted by homes


At that rate, a compressor or defrost board that's failing and cycling hard adds up fast on your bill before it quits for good. A technician pricing a repair against a new unit is weighing that cost against what you're already paying to run it.
EIA-861 2025 statewide residential average

They flip it back, the unit runs for an hour, and it trips again. They call around to a few Indiana companies, explain the breaker, the humming, the age of the outdoor unit, and get three different guesses over the phone before anyone looks at it. Each call starts over from nothing, and the system still isn't running.

One contractor gets the details once: the breaker, the humming, what you've already tried. They work on heat pumps all season and know a tripping breaker usually means the compressor or defrost board is failing, not the wiring. They come knowing what they're likely dealing with, and you're not fielding calls from four different companies while your house sits at 80 degrees.

Power isn't reaching the unit, the thermostat isn't calling, or a part inside the outdoor unit has failed. That's the whole list. A breaker, a disconnect, a defrost board, a compressor. Whichever one it is, it's not a mystery once someone's standing in front of it with a meter.
What it saves you is the part before that. You won't be the one pulling up a list of Indiana HVAC companies, calling three of them, describing the hum or the tripped breaker three separate times, and writing down three different guesses to compare. One licensed contractor near you gets the call, the one who already knows what tends to fail on these units after an Indiana summer, and you tell the story once.


No fee to send it, and nothing to sign.
A heat pump that won't start isn't something to leave for a few days and see what happens, especially once nights turn cold. One call gets a licensed Indiana contractor who works on these units every season out to look at the breaker, the disconnect, and the board before a small failure turns into a bigger repair.